1 / 5
| Technical Characteristics | Parameter | ||
| AC Input | Input | Single-phase three-wire system (L/N/PE) | |
| Input Voltage (V) | AC220V | ||
| Input Frequency | Rated input frequency: 50/60HZ, Fluctuation range: 45Hz~66Hz | ||
| Inrush Current | Under rated input conditions, the starting inrush current is not greater than the rated operating state of the input current peak value of 150% (from the current spikes caused by capacitance EMI does not consider) | ||
| Effectiveness / Power Factor | Effectiveness: ≥88% | Power factor: ≥0.9 | ||
| Model | IPS-RT11010 | ||
| DC Output | Output Power (W) | 1100W | |
| Output Voltage (V) | 110V DC | ||
| Rated Output Current (A) | 10A (Current values: 11A) | ||
| Regulators Accuracy | ≤±2V | ||
| Broadband Noise Voltage | ≤50mV (3.4KHZ~150KHz) | ≤20mV (0.15KHZ~30MHz) | ||
| Discrete Frequency Noise | ≤5mV (3.4KHZ~150KHz), ≤3mV (150KHZ~200MHz), ≤2mV (200KHz~500KHz), ≤1mV (0.5KHZ~30MHz) | ||
| Peak Noise Voltage | ≤150mV (20MHz bandwidth) | ||
| Inter-module Current Capacity | Parallel connection: The maximum and the minimum of the following difference 2A (above 10% load) | ||
| Security | Insulation Strength | Input to output: 1500VDC | Input to chassis: 1500VDC | Output to chassis: 500VDC | |
| Leakage Current | <1.5mA | ||
| Reliability | MTBF ≥ 100,000h | ||
| Cooling Method | Forced air cooling (internal rectifier DC fans, wind flow 42CFM) | ||
| Working Environment | Operating Temperature | -10°C ~ +50°C | |
| Storage Temperature | -40°C ~ +85°C | ||
| Relative Humidity | 10% ~ 90% (No condensation) | ||
| Mechanical Parameter | Dimensions (W*H*D) | 482 mm * 88 mm * 300mm (10A-60A) 482 mm * 88 mm * 350mm (80A-100A) |
|
| Weight | 8.5 KG (10A-60A), 12 KG (80A-100A) | ||